Fasten the two roof battens together via two fasteners mitre cut roof batten valley or hip rafter.
Timber roof battens span.
Note that spanman automatically calculates the weight of roof battens and adds it to the roof weight.
The imposed uniformly distributed live load in the main span.
Fasten the batten to every truss or rafter with a 12 x 40mm timber fixing screw minimum fixing size through each flange.
Stratco roof and ceiling battens are light yet strong offering an economical alternative to timber.
Maximum span of lintel mm sheet roof 240 x 35 3400 3000 2300 3300 2900 2200 2900 2600 2100 2600 2300 2000 240 x 45 3700 3200 2600 3500 3100 2500 3100 2800 2300 2800 2600 2200 roof area supported m2 size dxb mm note.
Timber battens for tile roofs must meet the requirements of as 1684 2 as 1684 3 or as 1720 1.
Press design to obtain sizes.
Spacing should be interpreted as the centre to centre distance between adjacent parallel members.
For alternative stress grades fixing methods larger spans pitched roofs wind classification c3 etc refer as 1684 residential timber framed construction.
Batten mid span lapped joins minimum of 300mm 300mm 300mm 300mm 50mm minimum lap rafter waste end to be under turn down lips on battens where they intersect if the overhang of the mitred roof batten exceeds 300mm.
We supply 38 x 38mm or 28 x 38mm non structural timber battens for tile roofs.
Required size for a given span.
Roof and ceiling battens.
Stramit top hats battens capacity tables important note the information contained within this brochure is as far as possible accurate at the date of publication however before application in a particular.
Roof load width rlw and floor load width flw can be determined from as1684 or from the images below.
The high performance values of steel roof battens means they are an increasingly popular choice for reroofing or for new builds using tile roofs.
For details of weights refer to about technical.
Span tables f7 rafters a maximum roof pitch of 25 degrees is assumed.
Fasten the batten to every truss or rafter with a m5 5 x 40mm batten zip minimum fixing size through each flange.
This is set by the roof use.
Fixing battens to timber.
Timber stress grade f17 seasoned hardwood f17 129.
The sizes and fixings assume pergolas are either roofed lightweight roofing 10 kg m3 or could have a roof installed at some future stage.
Construction details should be in accordance with as1684 2.
Fixing battens to steel.
Alternatively design in a specific timber or steel material type.
Fixing to roof sheets.